Part Number Hot Search : 
HN7G09FE TA124 2520C AN130 N25F80 W5NA100 Z5241B SA40011
Product Description
Full Text Search
 

To Download MPO60S48 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  input parameter conditions min. typ. max. units input voltage range universal 90 264 vac 127 373 vdc input frequency 47 63 hz input filter meets en 55022 class b; fcc class b input current see model selection guide inrush current cold start, 115 vac 32.0 a pk cold start, 230 vac 50.0 safety ground leakage current 264 vac 3.5 ma output parameter conditions min. typ. max. units output voltage/current see model selection guide output voltage tolerance see note 1 ?.0 % line regulation vin = min to max ?.5 % load regulation iout = 10% to 100% ?.0 % ripple & noise (20 mhz) see note 2 ?.0 % hold-up time 115 vac 8 msec 230 vac 100 temperature coef cient ?.05 %/? short circuit protection continuous (autorecovery) overload protection see note 3 150 % general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac isolation resistance 500 vdc 1,000 m isolation capacitance 4,700 pf emi/rfi conducted en 55022; en 61000-3-2, -3 emc compliance electrostatic discharge (esd) iec/en 61000-4-2, -6, -8, -11 rf field susceptibility iec/en 61000-4-3 electrical fast transients/bursts on mains iec/en 61000-4-4 surge iec/en 61000-4-5 switching frequency fixed 66 khz environmental parameter conditions min. typ. max. units operating temperature range ambient 0 +25 +50 ? storage temperature range -20 +85 ? cooling free air convection (see derating curve) humidity rh, non-condensing 95 % physical size 4.00 x 2.00 x 1.20 inches (101.60 x 50.08 x 30.48 mm) weight 5.21 oz (0.150 kg) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 200 khours safety standards ul 1950, en 60950 vibration sinusoidal 50~500 hz, 3.0 grms, period of 30 min each along x, y & z axis single output, 60w compact, open frame ac/dc power supplies key features: 60w output power universal 90-264 ac input en 60950 approved (ul) compact 2 x 4 in package eight standard models meets en 55022 b meets en 61000-4 >200 khour mtbf mpo-60s series electrical speci cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com
model selection guide mechanical dimensions connections derating curve notes: 1. output voltage tolerance is measured at nominal input and 60% load. 2. output ripple is measured at 20 mhz bandwidth using 0.1 f and 10 f capacitors connected in parallel as close to the power supply terminals as possible. 3. overload protection is provided by an internal ?iccup circuit. the unit recovers automatically when the fault condition is removed. 4. these units will operate at no load without damage. for most appli- cations however, mpd recommends that a minimum load always be used. contact the factory for more information. 5. each unit includes an input fuse (250v/2a). since this fuse is not eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.50) micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com other models are available. contact the factory for details www.micropowerdirect.com model number input output max output power (w) max output capacitance (f) ef ciency (%, typ) current (a) voltage (vdc) current (a) 115 vac 230 vac rated % min. mpo-60s-03 1.2 1.0 3.3 8.00 0.00 26 8,800 74 mpo-60s-05 1.2 1.0 5.0 8.00 0.00 40 8,800 78 mpo-60s-09 1.2 1.0 9.0 6.67 0.00 60 6,670 82 mpo-60s-12 1.2 1.0 12.0 5.00 0.00 60 5,000 84 mpo-60s-138 1.2 1.0 13.8 4.35 0.00 60 3,600 83 mpo-60s-15 1.2 1.0 15.0 4.00 0.00 60 3,600 85 mpo-60s-24 1.2 1.0 24.0 2.50 0.00 60 2,500 86 mpo-60s-48 1.2 1.0 48.0 1.25 0.00 60 770 88 input connector (cn1): molex 5273-03a or equivalent (one pin removed) mating housing: molex 5195-03 or equivalent mating terminal: molex 5293 or equivalent pin function 1 ac-neutral 2 removed 3 ac-line safety ground: the mounting holes marked ?se metal standoffs should be connected to the system earth ground via metal spacers or a cable. the input side mounting hole marked ?g provides the safety earth ground for the unit. this connection should be locked to prevent possible loosening. connecting the output side mounting hole improves emi. output connector (cn2): molex 5273-04a or equivalent mating housing: molex 5195-04 or equivalent mating terminal: molex 5293 or equivalent pin function 1+v out 2+v out 3-v out 4-v out


▲Up To Search▲   

 
Price & Availability of MPO60S48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .